P600 works with Beckhoff CU1123

P600 works with Beckhoff CU1123

This requires an EC_EXTEND file. It is for the followin product code and vendor ID.
From the ESI file: CU1123
See the attached file.  Rename it EC_EXTEND.TXT before using it in Motion Perfect.
    • Related Articles

    • Trio & Beckhoff EL7221 drive

      Beckhoff EL7221-9014 supports the MDP 742 and DS402 drive profiles. Both profiles contain the same parameters. They only differ in terms of the specified designations and the parameter index. Trio controller only works with DS402. User have to ...
    • Using an Ethernet switch for Ethercat

      EtherCAT cannot use a standard Ethernet Switch. If you want a Switch because it makes the topography of the wiring more convenient, then you need an an EtherCAT Swtich/hub such as the Beckhoff CU1128. Using a switch makes no difference to the logical ...
    • General EtherCAT Error

      Motion Coordinator reports a General EtherCAT Error with a number.  What does it mean? Error - General Ethercat Error(8) = invalid data, exceeded maximum telegram length (by attempting  to add too much data into the telegram.) Error - General ...
    • Fast EtherCAT start up.

      The fast startup is done with ETHERCAT(0,0,5). It means the master does not wait for the drives to be in sync before going operational. The drives will still take the same amount of time to get in sync so you should delay doing any actual moves until ...
    • EtherCAT start - diagnostic information

      When reporting an EtherCAT startup error, please send the following information to Trio technical support. 1) The text shown on the terminal after ETHERCAT(0, 0) For example: >>ETHERCAT(0,0) Warning - EtherCAT cable or network not detected (slot 0). ...