How many Flexslice modules can I fit to the P366 coupler?

How many Flexslice modules can I fit to the P366 coupler?

The EBUS power source from the coupler and Flex-6 Nano at 40 degrees celcius are:
P600 : 2700 mA maximum.
P366 : 2860 mA maximum.

The maximum number of modules is defined by the power on the EBUS and the propagation times over the EBUS data terminals. The absolute maximum is 16 modules dues to propagation delays. The actual maximum determined by power consumption can be calculated from these numbers:

P371, P372, P376, P377 : 150 mA per module
P375 : 330 mA per module
P379 : 220 mA per module
P378 : depending on analogue output load...
                       Worst case with 2K Ohm load on each Analog Output 650 mA
                       Case with 10K Ohm load on each Analog Output 440 mA
                       Case with no load 330 mA

Handy table of power multipliers.  Must add up to 16 or less.
Flexslice P367 P368 P369 P371 P372 P374 P375 P376 P377 P378 P379 P386 P387
Unit Load 1.25 1.25 1.25 1 1 2.5 2 1 1 4 1.25 1 1

    • Related Articles

    • Flexslice Loading/Configuration Limits - EBUS Load

      EBUS loading of the the Flex-6 Nano and the Flex Coupler (P366) is limited to 16. Attached is a spreadsheet to calculate your projects requirements and highlight any possible limitations.
    • Wire size for Flexslice I/O modules

      Trio's Flexslice modules use the a 10-way 3.5mm pitch, push fit connector: 15EDGKN-3.5-10P-13 from Degson. According to the manufacturer's datasheets (https://www.tme.eu/Document/580c900c7460c0af0ff973aec46ec4f5/15edgk.pdf) the maximum wire size is ...
    • Thermocouple Flexslice Module - P367

      P367 (Basic) Thermocouple Flexslice Module Attached is the Application Technote and example program to help in getting started. VR assignment is commented to correspond with the Application Technote. Drop Files to Attach
    • AN-399 TrioPC Motion Performance with Flex-6 Nano

      This document describes some timing tests with made with TrioPC motion Active X and Flex-6 Nano Motion Coordinator.
    • Flex Nano not connecting to EtherCAT or HMI (E09 Error)

      Please confirm that the firmware has been upgraded to 2.0318 or later with Bootloader V2.05 according to the technical bulletin. TB2202_Flex-6 and MC6N update. The Bulletin was distributed on 9th December 2022. After installing the update, the old ...