Flexslice Loading/Configuration Limits - EBUS Load

Flexslice Loading/Configuration Limits - EBUS Load

EBUS loading of the the Flex-6 Nano and the Flex Coupler (P366) is limited to 16.
Attached is a spreadsheet to calculate your projects requirements and highlight any
possible limitations.
    • Related Articles

    • How many Flexslice modules can I fit to the P366 coupler?

      The EBUS power source from the coupler and Flex-6 Nano at 40 degrees celcius are: P600 : 2700 mA maximum. P366 : 2860 mA maximum. The maximum number of modules is defined by the power on the EBUS and the propagation times over the EBUS data ...
    • Loading encrypted project from SD card

      This is the content for the SD card TRIOINIT.BAS ' *** ' SD Card decryption demo. ' Prepared by Trio Motion Technology Ltd. ' ' *** PROJECT_KEY "O5/A6qXkaXc" FILE "LOAD_PROJECT" "training ecr1" Replace the key above with yours and use your project ...
    • Thermocouple Flexslice Module - P367

      P367 (Basic) Thermocouple Flexslice Module Attached is the Application Technote and example program to help in getting started. VR assignment is commented to correspond with the Application Technote. Drop Files to Attach
    • Wire size for Flexslice I/O modules

      Trio's Flexslice modules use the a 10-way 3.5mm pitch, push fit connector: 15EDGKN-3.5-10P-13 from Degson. According to the manufacturer's datasheets (https://www.tme.eu/Document/580c900c7460c0af0ff973aec46ec4f5/15edgk.pdf) the maximum wire size is ...
    • Flexslice 24V digital input levels

      The P372 PNP 16 x Digital Input module has input threshold values to work with standard PLC IO systems.  If the input is below 5V then the input is OFF.  If the input is above 15V then the input will register as ON.