Out of the box, the ED3S drive will display Positive Overtravel and Negative Overtravel becasue it expects limit swtitches to be connected to the 24V inputs.

When overtravel inputs are not required, set Pn000.1 and Pn000.2 to 1.


    • Related Articles

    • Error display Exx - what do they mean?

      Error Display Codes Unn Unit error on slot nn - see SYSTEM_ERROR Ann Axis error on axis nn - see AXISSTATUS Cnn Configuration error on unit nn ie: too many axes - see SYSTEM_ERROR Exx processor / memory event - see SYSTEM_ERROR and FLASH_LOG E00 - ...
    • What does SERVO_OFFSET do?

      SERVO_OFFSET is a system parameter that is usually set by the operating system.  The value depends on the SERVO_PERIOD, the modules fitted (to a MC664X) and the model of Motion Coordinator.  It should not be necessary to set this in a system.  Only ...
    • AN-426 Using Touch Probe on ESTUN drive

      This Application Note shows how to use the Registration with Touch Probe Enabled on the ESTUN PRONET Drive (Pronet SUMMA will be used for Illustration)
    • EURO 404 - Motion Problem at SERVO_PERIOD 250

      A motion problem could occur when running MC403, MC405, Euro404 or Euro408 at 250 usec servo period. The moves would stop (buffers frozen) and an uncommanded movment could occur on one axis in an XY pair. The issue occured very infrequently and was ...
    • Servo feeder with measuring wheel.

      Good to hear from you. You shoule put the EtherCAT drive into CSV (speed mode) then it is possible to combine the EtherCAT axis with the encoder wheel as feedback. BASE(wheel) ATYPE = 44 ' (servo axis type) UNITS = UNITS AXIS(ecat_servo) DAC_SCALE = ...