Brake Current Ratings For Trio MX Range Motors
MXL
Range Motors
All
Brake Voltage Rated at 24Vdc ±10%
|
Motor
Size
|
Brake
Rated Power (W)
|
Brake
Operating Current (A)
|
Brake
Rated Torque (Nm)
|
|
50W
|
4.0
|
0.17
|
0.32
|
|
100W
|
4.0
|
0.17
|
0.32
|
|
200W
|
7.4
|
0.31
|
1.5
|
|
400W
|
7.4
|
0.31
|
1.5
|
|
750W
|
9.6
|
0.40
|
3.2
|
|
1KW
|
9.6
|
0.40
|
3.2
|
MXM
Range Motors
All
Brake Voltage Rated at 24Vdc ±10%
|
Motor
Size
|
Brake
Rated Power
|
Brake
Operating Current
|
Brake
Rated Torque (Nm)
|
|
1KW
|
19.5
|
0.82
|
12
|
|
1.5KW
|
19.5
|
0.82
|
12
|
|
2KW
|
19.5
|
0.82
|
12
|
|
3KW
|
35
|
1.67
|
40
|
Related Articles
DX5 Brake Motor Control
There are two parts to setting up the brake control for DX5 drives that have brake motors connected to them. 1. Set the DX5 drive module for the axis required for remote brake control. In Basic Setup set the Motor Brake Assignment to Brake ...
Trio Scara Motor & Drive Sizes
Trio Scara Motor & Drive Sizes Drop Files to Attach
Does the DX4 work with EMJ, EMG, EML or only with MXM, MXL?
DX4 supports EM3A and EMG motors (not EMJ and not EML). This is due to the encoder type fitted to the EMJ and EML motors. MXL (low inertia) and MXM (medium inertia) are Trio motors that best fit in a system with the DX4 drives.
Which ESTUN motors can I use with the Trio DX4?
EMG and EM3A may be used with the Trio DX4. They have the correct encoder type. The Trio MXM and MXL motors are of course perfect to use with the DX4 drives.
What is the ouput current of the 24V digital ouputs on DX4 drives?
The Digital Outputs of the DX4 drive have a maximum current capability of 30mA. Digital inputs have current limit resistors and are rated at 24V, max load less than 10mA. The ED3S (Summa) drive and the DX4 have the same range.