Touch probe problem when motor direction reversed
With EtherCAT touch probe it is not possible to reverse the axis direction with ENCODER_RATIO and STEP_RATIO. Instead you must reverse the direction in the servo drive itself. Check the operating and setup manuals for the drives you have connected to the Trio EtherCAT master.
Related Articles
AN-291 Touch Probe EtherCAT registration
Digital Servo Drives often have a position capture function known either as Touch Probe or Touch Trigger. This function uses either the Z mark on the motor’s encoder, or one of 2 external inputs to act as the latch signal and capture the encoder ...
AN-426 Using Touch Probe on ESTUN drive
This Application Note shows how to use the Registration with Touch Probe Enabled on the ESTUN PRONET Drive (Pronet SUMMA will be used for Illustration)
DATUM(6) with MC664 and EtherCAT drives
You must set up the PDO to include the Touch Probe objects. If it is a drive with profiles built-in to the trio firmware, then the usual selection is DRIVE_PROFILE = 2 in position mode. If using an EC_EXTEND file then you must add the touch probe to ...
Jitter on the direction output, MC403-Z P821
When using a MC403-Z P821, we are facing with an issue related to the "direction" signal. Please take a look at the following picture: Scope screen We have connected the oscilloscope on the step signal (channel 1) and direction signal (channel 2). ...
AN-396 EtherCAT Registration
Registering is a way of very accurately noting a position on an axis. This document discusses how to perform this registration, as well as provides more information on the Motion Coordinators (to which this is applicable) and on Touch Probe