AN-410 Setting EtherCAT address on RTA drive
RTA EtherCAT drives run on the EtherCAT network with a Trio Motion Coordinator as the EtherCAT master.
This document shows how to set the Configured Alias Address for the drive
Related Articles
Changing EtherCAT drive address
There are 3 methods to set the address in the servo-drive; 1 . If there are rotary address switches on the front of the drive, then they may be used to select the address. 2. The address may be set in memory, either via a front panel keypad or ...
AN-315 EtherCAT setup for Panasonic A5B Drive
When delivered, the Panasonic A5B has 2 features set; the Positive Over Travel Input (POT) and the Negative Over Travel input (NOT). If these are connected to limit switches then the system will work in the usual way until the limit switch is ...
AN-315 EtherCAT setup for Panasonic A5B Drive
The recommendations within this document applies to the Trio MC464+P876 EtherCAT master and the Trio MC4N-ECAT EtherCAT Master used with the Panasonic Minas A5B EtherCAT servo drive. When delivered, the Panasonic A5B has 2 features set; the Positive ...
DRIVE_STATUS issue (EtherCAT CoE status word)
DRIVE_STATUS is the value of the CoE status word. Object number 0x6041. If bit 11 is set in the status in the drive then we must see the same in DRIVE_STATUS. If not then the drive is not setting the bit in Object 0x6041. You can check the object ...
Torque and speed control over EtherCAT
For most servo drives, set DRIVE_MODE in the MC_CONFIG. On EtherCAT startup, the Trio Master will set up the drive for the selected mode and set the ATYPE automatically. Some drives can change mode after EtherCAT startup. In the PDO you will see the ...