Related Articles
Error display Exx - what do they mean?
Error Display Codes Unn Unit error on slot nn - see SYSTEM_ERROR Ann Axis error on axis nn - see AXISSTATUS Cnn Configuration error on unit nn ie: too many axes - see SYSTEM_ERROR Exx processor / memory event - see SYSTEM_ERROR and FLASH_LOG E00 - ...
Question about Omron R88D and Trio Firmware 2.0296
The most likely issue is that the R88D cannot use the Trio as clock master in that Trio firmware version. You must add this command to force the first drive to be Distributed Clocks Master. Set the first drive with DC capability to be the Distributed ...
AN-319 Change of Coordinate system
This document demonstrate how to change the coordinate system of a machine from the world system to the object system given three points of the object. This example use an example points to change the coordinate system of the machine from the red one ...
AN-335 Gantry Error Compensation
This document explains how to correct the position error between the two motors commanding the Gantry axis (longitudinal axis) of advanced Gantry systems
CAN IO Address Problem
The Leds on the module are a binary code. LEDs 8, 9 and 10 ON woud be code 7 = System Shutdown. Usually this is caused by interference on the CAN lines. Check the correct screened cable has been used and that both ends are terminated with 120 Ohm ...