CANbus port check

CANbus port check

MC403, MC405, Euro404 and Euro408 Motion Coordinators that appear to have a failed CANbus port.

Check that the CANIO_ADDRESS is set to 32 when using Trio CANIO mode or to 40 .. 42 when using CanOpen. The CANIO_ADDRESS is stored in Flash in the above Motion Coordinators so will remember the setting even if removed from the MC_CONFIG. Check in the Motion Perfect terminal #0 by typing PRINT CANIO_ADDRESS.

>>PRINT CANIO_ADDRESS
32
>>
    • Related Articles

    • CAN IO Address Problem

      The Leds on the module are a binary code. LEDs 8, 9 and 10 ON woud be code 7 = System Shutdown. Usually this is caused by interference on the CAN lines. Check the correct screened cable has been used and that both ends are terminated with 120 Ohm ...
    • AN-316 CANOpen IO Setup Guide

      There are 2 modes of CAN operation available: 1. Trio CANbus protocol. This is the default protocol and is tailored for the high performance Input/Output needed in a Motion System. 2. CanOpen to Can in Automation standards CiA301 and CiA401. Option 2 ...
    • Could not restart CANIO with CANIO_STATUS

      CAN IO modules went into error and could not be reset by CANIO_STATUS.4 = 1. After some tests, the customer found the issue was as follows: It was solved by providing isolation for Trio and Can IO module from the panel. Also used separate 24V supply ...
    • Changing EtherCAT drive address

      There are 3 methods to set the address in the servo-drive; 1 . If there are rotary address switches on the front of the drive, then they may be used to select the address. 2. The address may be set in memory, either via a front panel keypad or ...
    • Uniplay HMI IP Address Change Using Motion Perfect

      A video is available on our Trio Website showing how to carry out the IP address of your Uniplay 7 or 10 HMI. Please follow this link. http://www.triomotion.uk/system/downloadPage.php?location=%2Fvideos%2FUniplay_HMI