Panasonic A5 & A6 Drive with Trio controllers
The Panasonic A5 & A6 Drive has 2 features set; the Positive Over Travel Input (POT) and the Negative Over Travel input (NOT). If these are connected to limit switches then the system will work in the usual way until the limit switch is triggered. If limit switches are not connected, then the servo drive must have the POT and NOT functions disabled. Please follow instruction as per Application Note AN-315
Related Articles
AN-315 EtherCAT setup for Panasonic A5B Drive
The recommendations within this document applies to the Trio MC464+P876 EtherCAT master and the Trio MC4N-ECAT EtherCAT Master used with the Panasonic Minas A5B EtherCAT servo drive. When delivered, the Panasonic A5B has 2 features set; the Positive ...
AN-315 EtherCAT setup for Panasonic A5B Drive
When delivered, the Panasonic A5B has 2 features set; the Positive Over Travel Input (POT) and the Negative Over Travel input (NOT). If these are connected to limit switches then the system will work in the usual way until the limit switch is ...
AN-360 Flexible configuration with Panasonic Drive
The standard EtherCAT profiles built in to the MC4 and MC6 range firmware have fixed mode operation that is defined at startup using DRIVE_MODE. In some cases the user may want to change the axis mode without re-starting the EtherCAT network. Some ...
Trio Scara Motor & Drive Sizes
Trio Scara Motor & Drive Sizes Drop Files to Attach
AN-292 Configuring the Panasonic A4B over RTEX
The Panasonic A4N servodrive, when connected to the MC464 over RealTime Express (RTEX) can be set up using the Motion Perfect v3 Intelligent Drives window. This document is a short guide to using MPv3 to set up the A4N position loop servo gains.