Recovering project file from MC2xx

AN-401 Recovering project from MC2xx

When programs are not “Fixed” in the Motion Coordinator’s Flash EPROM, there is a chance that the programs may be lost due to low battery voltage or an external event corrupting the RAM.

This document will be helpful If the Motion Coordinator will not start the machine on power up and you cannot connect Motion Perfect to synchronise with the Project files
    • Related Articles

    • MC206X - Flash EPROM or RAM?

      MC206X can use the Flash Memory on power up. It depends on the setting of the POWER_UP paraemter. If POWER_UP = 1 then it will copy the programs from Flash to RAM on each power up. If set to 0, then it uses the RAM on power up and does not copy from ...
    • MC_CONFIG vs Flash parameters

      All Motion Coordinators store the IP_ADDRESS, IP_NETMASK and IP_GATEWAY in Flash memory.  So there is usually no need to add them to the MC_CONFIG. There are some differences with other system parameters. MC4N-ECAT, MC4N-RTX, MC6N-ECAT, Flex-6 Nano ...
    • AN-367 RAM battery issue used in Euro205x, Euro209 & MC206x

      The Motion Coordinators Euro205x(P151), Euro209 (P159), & MC206X(P136), contain a Mini Nickel Metal Hydride Button Cell Battery, to maintain the RAM memory contents when the Motion Coordinator is not powered. This document explains the details of the ...
    • AN-318 MC2xx Battery backed RAM

      This document explains about the battery backed RAM of MC2xx series controller The MC224 has a non-rechargeable Lithium Ion battery. The nominal lifetime is 10 years before replacement is necessary. See AN-257 “Replacing MC224 battery”
    • Trio Project Keys

      I used to be able to generate project keys for Trio’s that are out in the field by using the Motion Perfect 2 project encryptor. I’d put the last 5 digits of the serial number in and that would give me the project key so I could make SD cards with ...